Doors

Map Requirements

Before a door can be properly integrated, be sure to draw up the door locations with the correct door names on the navigation graph using traffic_editor. The instructions to do so can be found in the Traffic Editor chapter.

Integration

Door integration is required when integrating RMF into a new environment. For hopefully obvious reasons, only automated doors can be integrated with RMF though it may be possible to trigger an alert to a designated human to open a manual door but this is not recommended. An automated door can be defined as an electronically powered door that is remotely controllable, either using a remote trigger or has been outfitted with a computing unit capable of commanding the door to open and close when needed, using certain interfaces.

Doors can be integrated with RMF using a ROS 2 door node and a door adapter, which we sometimes refer to as a door supervisor. The block diagram below displays the relationship and communication modes between each component:

The door node will have to be implemented based on the make and model of the door that is being integrated in order to address the specific API of the door controller module. The communication protocol will also be dependent on the door and controller model, which might be some form of REST, RPCXML, etc. The door node is in charge of publishing its state and receiving commands over ROS 2, using the messages and topics listed below:

Message TypesROS2 TopicDescription
rmf_door_msgs/DoorState/door_statesState of the door published by the door node
rmf_door_msgs/DoorRequest/door_requestsDirect requests subscribed by the door node and published by the door adapter
rmf_door_msgs/DoorRequest/adapter_door_requestsRequests to be sent to the door adapter/supervisor to request safe operation of doors

The door adapter stands in between the rest of the RMF core systems, fleet adapters, and the door node, and acts like a state supervisor ensuring that the doors are not acting on requests that might obstruct an ongoing mobile robot task or accidentally closing on it. It keeps track of the door state from the door node, and receives requests from the adapter_door_requests topic which are published by either fleet adapters or other parts of the RMF core system. Only when the door adapter deems that a request is safe enough to be performed, it will instruct the door node using a request. It should also be noted that direct requests sent to the door node, without going through the door adapter will be negated by the door adapter, to return it to its prior state in order to prevent disruptions during operations with mobile robots.

Door Adapter Template

To make the process of integrating doors with RMF even simpler, we have open-sourced a template package where users only need to update certain blocks of code with the API calls to their specific door controller.